Precision Electronics Repair
12-month warranty on every repair — workmanship and parts.

Air conditioning PCB repair

Inverter boards, IPM power modules, filter boards and control boards repaired at component level, instead of replacing the whole board or the unit. For installers, maintenance firms and the public. Drop off by appointment in Watford, or post your board from anywhere in the UK.

Book a repair

Our own in-house tester

Testing in hours, not days

We've developed our own bench tester for air conditioning boards. It runs the checks that would otherwise take days of manual testing, so your board comes back sooner.

Faster turnaround

Testing a board by hand on the bench can take days. On our tester, the checks take hours, so you get your board back sooner.

Every board tested the same way

The tester runs the same checks every time and records the results, so nothing gets missed.

Proven before it leaves

For the inverter (IPM) board, it checks every switch in the power module and its drive circuit. For the filter board, it checks the mains path through the board, the communication circuit and the current sensor.

Built in-house

We designed and built it ourselves for the boards we see most. It currently covers the Fujitsu K03CE-C-A outdoor IPM board and the K03BX-C-A filter board, and more testers are in development. Other boards are tested by hand for now.

Air con boards we repair

Send the board, not the unit.

Inverter and IPM boards

Outdoor inverter boards and their power modules (IPMs), the boards that drive the compressor.

Filter and noise boards

The board where mains comes in, including its fuses, filtering and current sensing.

Indoor and outdoor control boards

Main control boards for indoor and outdoor units, including communication faults between them.

Power supply boards

Switch-mode power supplies on air con boards that fail and take the rest of the unit down.

Remote controls

Remote control boards, including battery leak corrosion.

All makes

Boards from all makes of split and multi-split units. Tell us the make and board number when you book.

Recent air con work

Every repair is photographed at each stage, and you get the pictures.

Sanyo air conditioning outdoor fan speed control board on the bench with test leads attached

Sanyo outdoor fan speed control board

Two relay flyback diodes had failed open, and two transistors were replaced. Bench tested on 24 V, with each output switching mains into a test load, then a one-hour soak test.

Air conditioning control board with large electrolytic capacitors

Air conditioning control board

Power module, three-phase bridge rectifier and two resistors replaced. A board like this is usually quoted as a whole-unit replacement.

Remote control board with corroded battery terminal area cleaned and repaired

Air conditioning remote

Leaking batteries had corroded the terminals badly. Terminals replaced and the board cleaned up.

Air con stopped working? Check these first

Worth a few minutes before you have the board removed.

Check the power

  • Check the isolator switch and the circuit breaker for the unit.
  • Check the batteries in the remote.

Note the error code

  • Most units show an error code or a flashing light pattern when they stop. Write it down and tell us when you book — it helps us find the fault faster.

Stay safe

  • Don't open the outdoor unit. Air con boards run at mains and high DC voltages, and capacitors can hold a dangerous charge long after the power is off. Have a qualified engineer remove the board.

Prices

Every repair includes a 12-month warranty on our workmanship and on any replacement parts.

Quoted individually. Every air con board is different, so we quote before any work. No repair work starts until you've approved the price.

Parts are charged separately where needed. If we post it back, return postage is added at cost. If we can't repair it, there's no charge for our time. Full details in our terms.

Two ways to get it to us

Drop off in Watford

By appointment. Collect it in person and there's no postage to pay.

Post it

From anywhere in the UK. Return postage is charged at exactly what the carrier charges us.

12-month warranty

Our workmanship and any replacement parts are guaranteed for 12 months. Your statutory rights are not affected.

Common questions

Do I need to send the whole unit?

No. Just send the board, removed by a qualified engineer. Tell us the make, the model of the unit and the board number printed on it.

How long does it take?

For the boards our in-house tester covers, testing takes hours rather than days once your board is on the bench. Other boards are tested by hand for now, which takes longer. More testers are in development. We don't promise a repair date before we know the fault.

Which brands do you repair?

All makes. Our tester currently covers the Fujitsu K03CE-C-A outdoor IPM board and the K03BX-C-A filter board, with more testers in development. Other boards are diagnosed and tested by hand.

How much does it cost?

Every air con board is quoted individually. No repair work starts until you've approved the price, and if we can't repair it there's no charge for our time.

Do you work with installers and maintenance firms?

Yes. We repair boards for air conditioning installers and maintenance firms, as well as for the public.

What warranty do I get?

Our workmanship and any replacement parts are guaranteed for 12 months. It covers the repair we carried out. Every repaired board has a numbered warranty sticker, which needs to stay in place. Your statutory rights are not affected.

Other boards? See our circuit board repair and UK mail-in board repair pages.

Got an air con board that's failed?

Tell us the make, the board number and the error code, and we'll email you a free, no-obligation estimate.

Book a repair